The Laminar Air Flow (HORIZONTAL) from AGN Enterprises is a laboratory workstation designed to provide a clean, controlled working environment for suitable procedures that require filtered air. In this configuration, filtered air moves horizontally across the work area toward the operator.
This type of workstation is commonly used for applications where protection of the work product or materials from airborne particulate contamination is important. It can support suitable activities in biotechnology, microbiology, tissue culture, pharmaceutical research, electronics assembly, and educational laboratories.
The horizontal airflow arrangement provides a convenient working area for procedures that benefit from a continuous supply of filtered air. However, a laminar airflow workstation is primarily intended to protect the work from contamination and should not be considered a substitute for a certified biological safety cabinet when personnel or environmental protection is required.
| Model No. | Description | Dimensions (W x D x H) | Features |
| AGN-158-A | Laminar Air Flow (Horizontal) with S.S. Workbench | 60 x 60 x 60 cm | Microprocessor control & alarm |
| AGN-158-B | Laminar Air Flow (Horizontal) with S.S. Workbench | 90 x 60 x 60 cm | Microprocessor control & alarm |
| AGN-158-C | Laminar Air Flow (Horizontal) with S.S. Workbench | 120 x 60 x 60 cm | Microprocessor control & alarm |
| AGN-158-D | Laminar Air Flow (Horizontal) with S.S. Workbench | 180 x 60 x 60 cm | Microprocessor control & alarm |
| AGN-158-E | Laminar Air Flow (Horizontal) with S.S. Workbench | 60 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-F | Laminar Air Flow (Horizontal) with S.S. Workbench | 90 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-G | Laminar Air Flow (Horizontal) with S.S. Workbench | 120 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-H | Laminar Air Flow (Horizontal) with S.S. Workbench | 180 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-I | Laminar Air Flow (Horizontal) – Complete S.S. | 60 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-J | Laminar Air Flow (Horizontal) – Complete S.S. | 90 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-K | Laminar Air Flow (Horizontal) – Complete S.S. | 120 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-K(a) | Laminar Air Flow (Horizontal) – Complete S.S. | 180 x 60 x 60 cm | 304 Grade Stainless Steel |
| AGN-158-L | Laminar Air Flow (Horizontal) – Mild Steel | 60 x 60 x 60 cm | Epoxy Powder-Coated Mild Steel |
| AGN-158-M | Laminar Air Flow (Horizontal) – Mild Steel | 90 x 60 x 60 cm | Epoxy Powder-Coated Mild Steel |
| AGN-158-N | Laminar Air Flow (Horizontal) – Mild Steel | 120 x 60 x 60 cm | Epoxy Powder-Coated Mild Steel |
| AGN-158-N(a) | Laminar Air Flow (Horizontal) – Mild Steel | 180 x 60 x 60 cm | Epoxy Powder-Coated Mild Steel |
| AGN-158-O | Laminar Air Flow Workstation (Horizontal) | 60 x 60 x 60 cm | Touch Panel Mild Steel |
| AGN-158-P | Laminar Air Flow Workstation (Horizontal) | 90 x 60 x 60 cm | Touch Panel Mild Steel |
| AGN-158-Q | Laminar Air Flow Workstation (Horizontal) | 120 x 60 x 60 cm | Touch Panel Mild Steel |
| AGN-158-R | Laminar Air Flow Workstation (Horizontal) | 150 x 60 x 60 cm | Touch Panel Mild Steel |
| AGN-158-S | Laminar Air Flow Workstation (Horizontal) | 60 x 60 x 60 cm | Touch Panel Stainless Steel |
| AGN-158-T | Laminar Air Flow Workstation (Horizontal) | 90 x 60 x 60 cm | Touch Panel Stainless Steel |
| AGN-158-U | Laminar Air Flow Workstation (Horizontal) | 120 x 60 x 60 cm | Touch Panel Stainless Steel |
| AGN-158-V | Laminar Air Flow Workstation (Horizontal) | 150 x 60 x 60 cm | Touch Panel Stainless Steel |
The Laminar Air Flow (HORIZONTAL) uses a filtration system to provide a continuous flow of filtered air across the working chamber. Air travels horizontally through the work area, helping reduce the presence of airborne particles around suitable materials and samples.
Consequently, the workstation can provide a cleaner environment for procedures where contamination control is important. Users should maintain appropriate aseptic techniques and follow the manufacturer’s operating instructions throughout laboratory work.
Moreover, the horizontal configuration allows filtered air to travel directly across the working surface. This arrangement can be useful for applications where the direction of airflow suits the laboratory process.
The equipment can support suitable activities in:
In addition, universities and research centres can use the workstation for practical demonstrations and controlled sample-handling activities.
A controlled filtered-air workstation can help maintain a cleaner working area during appropriate procedures. Therefore, it can support laboratory workflows where airborne particles may affect sensitive materials.
The horizontal configuration also gives users a clear working area and provides a continuous flow of filtered air across the workspace. Furthermore, the workstation can help laboratories organize contamination-sensitive activities within a dedicated area.
However, users should select equipment according to the specific hazards involved. A laminar airflow workstation does not provide the same protection as a biological safety cabinet for work involving potentially hazardous biological agents.
The Laminar Air Flow (HORIZONTAL) is suitable for schools with advanced laboratories, colleges, universities, biotechnology institutes, pharmaceutical research facilities, and other scientific institutions.
Teachers can use the equipment to demonstrate clean laboratory practices, while researchers can incorporate it into appropriate sample preparation and contamination-sensitive workflows. As a result, the workstation can support both educational and research requirements.
AGN Enterprises supplies laboratory equipment for educational, scientific, research, and institutional applications. This horizontal configuration provides a practical filtered-air workspace for suitable clean laboratory procedures.
Before ordering, laboratories should confirm the required working dimensions, airflow direction, filtration system, electrical specifications, installation requirements, and applicable performance or certification requirements.