| Specification | Details |
| Instrument Type | Laboratory Moisture Analyzer |
| Measurement Principle | Thermogravimetric moisture determination by simultaneous weighing and controlled heating |
| Maximum Weighing Capacity | Minimum 50 g |
| Mass Readability | 0.1 mg |
| Moisture Readability | 0.0001% |
| Repeatability – 2 g Sample | ≤ 0.05% SD |
| Repeatability – 10 g Sample | ≤ 0.02% SD |
| Heating Technology | Infrared halogen heating |
| Heating Design | Circular halogen lamp with reflector/heating chamber arrangement for rapid and uniform heating |
| Heating Performance | Rapid and uniform heating for accurate and reproducible moisture determination |
| Heating Chamber | Engineered chamber for uniform sample heating |
| Temperature Range | Up to 175°C minimum |
| Extended Temperature Range | Up to 250°C, where available |
| Temperature Increment | 1°C |
| Heating Profiles | Standard, Gentle, Rapid, Step and High Temperature |
| Switch-Off Criteria | Auto, Manual, Timed, User Defined Weight/Time, User Defined % Unit/Time and Intelligent |
| Intelligent Method Development | Automatic/intelligent method development facility |
| Measurement Units | % Moisture (%M), % Dry Matter (%D), % Ratio (%R) and other supported units |
| Additional Units | g/L, %M Atro and %D Atro, where supported |
| Method Memory | Minimum 40 methods |
| Batch Memory | Minimum 100 batches |
| Batch-Wise Storage | Batch-wise storage for routine and production applications |
| Measurement Data Memory | Up to 1,000 moisture determinations/results |
| Data Storage | Method-wise and batch-wise data storage |
| Statistics | Statistical display and printing of stored measurements |
| Statistical Data | Statistics based on Method or Batch |
| Drying Graph | Graphical display with auto-updating drying/moisture curve |
| Display | Graphical LCD display with LED backlight |
| Display Information | Measurement parameters, moisture results and drying process information |
| Password Protection | Password protection for secure access and parameter/data control |
| User Identification | User ID facility with inclusion in reports |
| Method Designation | Alphanumeric method designation |
| Serial Number Identification | Instrument serial number identification in system/reports |
| Method Linking | Method linking facility |
| Calibration | Balance and temperature calibration facility |
| Calibration Record | Calibration status and information tracking/recording |
| Calibration Reporting | Printable calibration report, where supported |
| GLP/GMP | GLP/GMP-compliant and user-configurable operation |
| GLP Printout | ISO/GLP-compliant recording and printout facility |
| Print Format | User-configurable/selectable print format |
| Communication Interface | RS-232C bidirectional interface |
| Software Compatibility | OEM-supported communication and reporting software |
| USB Interface | USB interface |
| Ethernet Interface | Ethernet interface |
| Sample Pan Material | Corrosion-resistant aluminium/stainless-steel laboratory-grade sample pans |
| Direct Printing | Direct printing of measurement results through compatible printer |
| External Printer | Compatible statistical data printer supplied with the system |
| Printer Type | Statistical Data Printer |
| Printer Compatibility | Fully compatible with the offered Moisture Analyzer |
| Printer Interface | Required communication/interface cable and accessories included |
| Printer GLP Function | ISO/GLP-compliant printout facility |
| Printer Date/Time | Date and time printing facility |
| Printer User ID | User identification facility, where configured |
| Printer Statistics | Printing of statistical data generated by the analyzer |
| Printer Totalization | Totalization function, where supported |
| Print Consumables | Initial printer consumables for installation and demonstration |
| Power Supply | 230 V / 50 Hz or suitable Indian equivalent |
| Power Consumption | Maximum approximately 415 W |
| Dimensions (W × D × H) | Approximately 211 × 342 × 187 mm |
| Net Weight | Approximately 7 kg |
| Gross Weight | Approximately 8 kg |
| Heating Reproducibility | Uniform and repeatable heating performance for consistent moisture determination |
| Analytical Weighing Technology | High-precision weighing technology suitable for moisture analysis |
| Measurement Stability | Stable weighing performance throughout moisture determination |
| Standby Temperature | Standby temperature facility, where available |
| Heating Verification | Heating profile and temperature operation verifiable during demonstration |
| Endpoint Stability | Stable endpoint determination during moisture analysis |
| Heating Consistency | Repeatable and consistent heating performance between consecutive analyses |
| Weighing System Protection | Internal weighing system designed to maintain analytical stability during heating |
| Sample Pan Stability | Stable sample pan positioning and handling during operation |
| Heating Recovery | Rapid recovery of heating stability after chamber opening/closing |
| Environmental Suitability | Suitable for standard laboratory humidity and environmental conditions |
| Internal Electronics Protection | Electronics suitable for standard laboratory operating conditions |
| Laptop/Desktop System | Compatible computer/laptop system for operation, data transfer, reporting, software communication and instrument integration, where applicable |
| External Printer Requirement | Separate compatible printer supplied with the Moisture Analyzer system |
| UPS / Power Backup | Suitable UPS/power backup system for safe operation and protection against power interruption/fluctuation |
AGN Enterprises supplies this laboratory moisture testing instrument for pharmaceutical, food, chemical, agricultural, and research applications. The halogen heating system provides controlled sample heating during analysis. Meanwhile, the integrated weighing mechanism monitors changes in sample mass throughout the drying process.
The touch-screen interface provides convenient access to operating functions and test information. Moreover, users can prepare a sample, select suitable test conditions, and monitor the analysis from one integrated instrument. This arrangement reduces the need for separate weighing and drying equipment.
The compact benchtop design also helps laboratories use available workspace efficiently. Furthermore, the instrument supports routine testing of suitable powders, granules, food materials, chemicals, pharmaceutical materials, and agricultural samples. Available capacity, readability, temperature range, programs, and connectivity can vary according to the selected configuration.
Quality-control laboratories use halogen moisture analysers to evaluate moisture content in raw materials and finished products. In addition, research laboratories can use them during formulation studies, material evaluation, and product development.
Food laboratories can analyze suitable ingredients and processed samples. Similarly, pharmaceutical and chemical laboratories can perform routine moisture testing as part of their quality procedures. Agricultural laboratories can also evaluate suitable grains, powders, and related materials.
Consequently, the analyser provides a versatile solution for laboratories requiring rapid moisture determination with straightforward operation.
AGN Enterprises provides laboratory instruments with an emphasis on dependable operation, practical design, and quality construction. Our team checks every instrument before dispatch. Moreover, we can provide suitable configurations according to specific laboratory requirements.
Customers can contact us for available weighing capacity, readability, heating temperature, and other technical specifications. We also provide competitive pricing, prompt delivery, customization support, and responsive customer service.